Enhancing Material Testing Solutions for Syringe and Needle Industries

In the dynamic landscape of material testing, where precision and reliability are paramount, Cell Instruments Co., Ltd. stands as a beacon of excellence. Specializing in a diverse range of material testing instruments, we cater to industries such as packaging, food, medical, pharmaceuticals, adhesives, beverages, cosmetics, textiles, plastics, electronics, and quality inspection agencies. At the forefront of our offerings are solutions tailored for syringe and needle manufacturers, ensuring compliance with stringent standards like ISO 7886-1, ISO 7886-2, ISO 7886-4, and ISO 7864.

Advancing Technology for Syringe and Needle Testing

In our pursuit of excellence, we continually refine our technology to meet the evolving needs of the industry. Our focus extends to enhancing the testing capabilities for syringes and needles, crucial components in medical and pharmaceutical applications. Through innovative design and meticulous engineering, we provide solutions that address key parameters outlined in ISO standards.

Verifying Design Integrity with ISO 7886-1

ISO 7886-1 delineates comprehensive test methods to ensure the integrity of sterile hypodermic syringes for single use. Our instruments facilitate the verification of crucial design aspects, including air leakage, dead space determination, liquid leakage, and operational forces. By adhering to these standards, manufacturers can instill confidence in their products' reliability and safety.

Precision Testing for Syringe Plunger Stopper

Our testing methodology meticulously evaluates the air leakage past the syringe plunger stopper during aspiration, guaranteeing optimal performance in clinical settings. Additionally, we ascertain the separation of the plunger stopper and plunger, a critical factor in preventing medication errors and ensuring accurate dosage delivery.



Minimizing Dead Space for Enhanced Efficiency

Dead space determination is integral to syringe design, impacting medication wastage and dosage accuracy. Leveraging our testing solutions, manufacturers can precisely measure and minimize dead space, optimizing efficiency while minimizing resource utilization.

Ensuring Liquid Integrity under Compression

Liquid leakage at the syringe plunger stopper under compression can compromise medication efficacy and patient safety. Our test methods enable rigorous evaluation of liquid integrity, ensuring leak-proof performance under varying pressure conditions.


Streamlining Operational Forces

The determination of forces required to operate the piston is vital for user experience and ergonomic design. Our instruments provide precise measurements, allowing manufacturers to fine-tune operational forces for seamless syringe usability.

Syringe Compatibility with Power-driven Syringe Pumps (ISO 7886-2)

In an era of automation, syringes compatible with power-driven pumps are gaining prominence for their efficiency and accuracy. ISO 7886-2 outlines test methods tailored for such syringes, ensuring compatibility and performance consistency with automated systems. Our testing solutions facilitate compliance with these standards, enabling seamless integration into automated medical workflows.

Safeguarding Against Reuse with ISO 7886-4

Preventing unauthorized reuse is paramount for single-use syringes to mitigate the risk of cross-contamination and ensure patient safety. ISO 7886-4 specifies test methods to assess the efficacy of reuse prevention features. Our instruments enable manufacturers to validate the integrity of these features, reinforcing product security and regulatory compliance.

Meeting Needle Standards with ISO 7864

Sterile hypodermic needles are indispensable components of medical procedures, demanding stringent quality assurance measures. ISO 7864 sets forth requirements and test methods to evaluate needle quality and performance. From fragmentation tests to flow rate determination, our testing solutions empower manufacturers to uphold the highest standards of needle integrity and reliability.

Conclusion: Empowering Syringe and Needle Manufacturers

In the realm of syringe and needle manufacturing, precision and reliability are non-negotiable. Jinan Xieo Electromechanical Co., Ltd. stands as a trusted partner, offering cutting-edge testing solutions tailored to industry standards. By ensuring compliance with ISO 7886-1, ISO 7886-2, ISO 7886-4, and ISO 7864, we empower manufacturers to deliver products of uncompromising quality, safeguarding patient well-being and upholding industry integrity.

Frequently Asked Questions (FAQs)

  1. What are the primary tests conducted for verifying syringe design integrity?

    • Our testing methodologies encompass air leakage, dead space determination, liquid leakage, and operational force analysis, ensuring comprehensive assessment of syringe performance.
  2. How do your solutions address the challenges associated with power-driven syringe pumps?

    • We offer test methods aligned with ISO 7886-2 to ensure syringe compatibility and consistent performance with power-driven pumps, streamlining automation in medical settings.
  3. What measures are taken to prevent unauthorized reuse of single-use syringes?

    • Our instruments facilitate adherence to ISO 7886-4 standards, enabling manufacturers to validate the effectiveness of reuse prevention features and enhance product security.
  4. What criteria are evaluated to ensure needle quality and performance?

    • ISO 7864 specifies stringent requirements and test methods, including fragmentation tests, flow rate determination, and needle bonding strength assessment, ensuring uncompromising needle integrity.
  5. How can Cell Instruments Co., Ltd. assist in custom testing requirements?

    • Our expertise extends beyond standard tests, encompassing customization and automation solutions tailored to specific client needs, ensuring comprehensive and reliable testing outcomes.
Contact us today for a test method and solutions